AXIS#.FAULT7015.ACTION

Description

This parameter determines the action the drive should take when F7015 occurs. If it is set to 1 or 4, the velocity will still be clamped at AXIS#.VL.LIMITN.

Parameter Value Drive Action
0 Disable Amplifier
1 Ignore (Fault will not be reported)
2 Controlled Stop
3 Dynamic Brake
4 Generate Warning (See W7015)

Versions

Action Version Notes
Implemented 02-10-04-000

General Information

Type

Read/Write

Units

N/A

Range

0 to 4

Default Value

1

Data Type

Integer

Stored in Non-Volatile Memory

Yes

Variants Supported

AKD2G

Fieldbus Information

EtherCATClosed ***EtherCAT is an open, high-performance Ethernet-based fieldbus system. The development goal of EtherCAT was to apply Ethernet to automation applications which require short data update times (also called cycle times) with low communication jitter (for synchronization purposes) and low hardware costs CoE and CANopen

Command

Index

SubIndex

Data Type

Units

Float Scale

Access

PDOClosed PDO is a type of protocol frame used in some fieldbuses. A PDO contains one or more object dictionary entries, which define the application data transferred between devices. Mappable

AXIS1.FAULT7015.ACTION

501ch

02h

Unsigned8

-

-

Read/Write

No

AXIS2.FAULT7015.ACTION

511ch

02h

Unsigned8

-

-

Read/Write

No

EtherNet/IP

Name

ID

Hex

Data Type

Access

Units

AXIS1.FAULT7015.ACTION

7201

1C21

Unsigned8

Read/Write

-

AXIS2.FAULT7015.ACTION

72737

11C2

Unsigned8

Read/Write

-

PROFINET

Parameter

PNU

Data Type

Access

Units

AXIS#.FAULT7015.ACTION

7201

Unsigned8

Read/Write

-